Silent Diesel Generator

20–3000kVA · 70–75 dB(A) at 7m · Weatherproof soundproof canopy

A silent diesel generator is a diesel genset built inside a sound-attenuating canopy, so it can run close to people without breaking noise limits. Wiseke Power manufactures soundproof canopy gensets from 20kVA to 3000kVA, powered by Cummins, Perkins, Weichai, Yuchai, SDEC, Baudouin and MTU engines. Every unit is factory load-tested before shipment, supplied with a weatherproof enclosure rated for permanent outdoor installation, and every unit ships with a load test report. All sets meet ISO 9001 and CE standards. Typical sound pressure is 70–75 dB(A) at 7 metres, against 95 to 105 dB(A) at 1 metre for the same engine on an open skid.

Three Canopy Families: Small, Large and Containerised

silent type genset

Small Power Silent Gensets, 20–100kVA

Compact single or three-phase units for shops, telecom shelters, clinics and small factories. A 20kVA set fits inside a 1.8 metre canopy and can be moved by forklift, while a 100kVA unit still clears a standard 2.2 metre doorway. Engine options include Perkins 1103A, Weichai WP2.3 and SDEC, with a base fuel tank for 8 hours of running at 100% load.

standard silent type genset

Large Power Silent Gensets, 120–1000kVA

The workhorse range for hospitals, hotels, factories and standby power. Common platforms are the Cummins 6C and 6L engines, Perkins 1106 and 2806 series, Weichai and Yuchai blocks, coupled to brushless alternators and Deepsea, Smartgen or ComAp control panels. All units come with auto start, remote start contacts and an optional ATS for mains failure changeover. Sound pressure stays at 70–75 dB(A) at 7 metres across the whole range.

containerized genset

Containerised Silent Gensets, 500–3000kVA

For 500kVA and above, a 20ft or 40ft container gives you a walk-in service aisle, external fuel connections and better heat rejection than a skinned canopy. The container wall carries the same acoustic lining, so noise stays at 70 dB(A) at 7 metres, and the unit can be shipped as a finished power house. See MTU Series 2000 and 4000 or Baudouin engines for this power band, or compare all enclosure formats on the open type diesel generator page.

What Makes a Genset Silent?

The canopy is not a box with sound-absorbing cotton stuffed inside. It does four jobs at the same time. High-density flame-retardant acoustic cotton absorbs mid and high frequency noise. The air intake and exhaust paths turn at least twice, so sound cannot escape in a straight line. An industrial-grade muffler sits inside the canopy, with flexible bellows that stop engine vibration from reaching the steel panels. Finally, anti-vibration mounts under the engine and alternator cut the low frequency rumble that thin enclosures cannot absorb. Lockable access doors with compression seals and a 2mm powder-coated steel shell complete an enclosure for outdoor use.

Silent Genset Noise Levels: What dB to Expect

Enclosure typeGenset sizeSound PressureTypical application
Open type, no canopy20–3000kVA95–105 dB(A) @ 1mPlant room,  mining places, remote site
Standard silent canopy20–1000kVA70–75 dB(A) @ 7mFactory, warehouse, construction site
Super-silent canopy20–600kVA65–69 dB(A) @ 7mHospital, hotel, residential area, office
Containerised soundproof500–3000kVA70 dB(A) @ 7mData centre, large outdoor standby power
A dB figure means nothing without three things: the distance, the load condition and the measurement standard. Sound pressure drops roughly 6 dB every time you double the distance outdoors, and the dB scale is logarithmic, so each 10 dB step sounds about twice as loud to the human ear. Noise figures on this page are typical values for each enclosure type,taken at 7 metres in free field at 75% load. Every set is load-tested before shipment and ships with its own test report. Where a project needs certified data, a third-party noise test to ISO 8528-10 can bearranged before delivery.

Standard Specifications

ParameterSpecification
Power range20–3000kVA (16–2400kW)
RatingsPrime (PRP), standby (ESP)  and continuously (COP)
Voltage127/220V,220/380V, 230/400V, 240/415V, 254/440V, 277/480V
Frequency50Hz or 60Hz
PhaseThree-phase four-wire; single-phase available up to 20kVA
Canopy protectionpowder-coated steel, lockable doors
Acoustic lining50mm glass wool with perforated galvanised liner
Fuel tankBase fuel tank, 8 hours  at 100% load,(12h / 24h separated fuel tank optional)
Control panelDeepsea DSE, Smartgen, ComAp, DEIF, full protection
AlternatorBrushless, Stamford,Leroy Somer, Marathon, MeccAlte,IP21 or IP23, class H insulation
CoolingRadiator cooled, 40 or 50 degrees C ambient 
Forklift PocketOptional.

Options That Change the Noise Number

Four options are worth deciding before you order. A residential silencer instead of the standard muffler typically drops 5 to 10 dB(A). An acoustic enclosure room built around the canopy takes another 10 dB, but needs airflow designed by an engineer. Anti-vibration spring mounts help most where the genset sits above living space or on a steel deck. And an ATS adds no noise, but decides whether the set starts by itself, so check the ATS selection guide for uninterrupted operation before you size the panel. Browse the full range of diesel generators for sale to compare formats.

Why Buy Silent Gensets from Wiseke Power

We have been building gensets for more than 15 years, and every silent unit leaves the factory after a full load test with a printed report. Recent shipments include 8 silent gensets delivered to a Ghana customer and 3 Perkins silent units with Stamford alternators, both built to the same canopy standard you see on this page. Send us your kVA, voltage, frequency and site condition, and you will have a technical proposal with the recommended canopy type and its typical noise level within 24 hours

Need a Quieter Genset?

Tell us the application and the distance to the nearest house, ward or site boundary, and our engineers will tell you which canopy meets that limit — before you order.

Scroll to Top